Bitte benutzen Sie diese Referenz, um auf diese Ressource zu verweisen: doi:10.22028/D291-47468
Titel: Planning Adjustment of Toric Capsular Bag Intraocular Lens Axis to Minimise Refractive Cylinder Outcome—A Calculation Concept Based on Vergence Transformations
VerfasserIn: Langenbucher, Achim
Szentmáry, Nóra
Cayless, Alan
Savini, Giacomo
Bolzern, Iwan
Fassbind, Benjamin
Hoffmann, Peter
Wendelstein, Jascha Armin
Sprache: Englisch
Titel: Diagnostics
Bandnummer: 16
Heft: 7
Verlag/Plattform: MDPI
Erscheinungsjahr: 2026
Freie Schlagwörter: toric intraocular lenses
toric IOL axis adjustment
spectacle refraction
paraxial optics
vergence calculation
ELP prediction model
DDC-Sachgruppe: 610 Medizin, Gesundheit
Dokumenttyp: Journalartikel / Zeitschriftenartikel
Abstract: Purpose: The aim of this study was to develop a concept for adjustment planning of intraocular lens orientation axes after cataract surgery with implantation of toric intraocular lenses (tIOLs) and to predict the spectacle refraction after tIOL re-alignment. Methods: This calculation concept based on paraxial spherocylindrical vergence transformations uses the actual spherocylindrical refraction at the spectacle plane, corneal power, and the labelled power and measured axis of the implanted tIOL to minimise the refractive cylinder by simulating the rotation of the tIOL in the eye. The axial lens position is derived from simple prediction models using anterior chamber depth and lens thickness or axial length from preoperative biometry or the equivalent tIOL power. The new target axis is predicted together with the spherocylindrical refraction after re-alignment of the tIOL. Results: To show the applicability of this calculation model, we provide four clinical working examples: example 1 deals with keratometric power values; example 2 deals with keratometric curvature values, including surgically induced astigmatism and a statistical posterior astigmatism correction for the cornea (both examples with a thin cornea model); example 3 deals with corneal curvature data for the front and back surface; and example 4 deals with keratometric power data and corneal back surface power data, including surgically induced astigmatism (both examples with a thick cornea model). Conclusions: The effect of tIOL axis adjustment after cataract surgery can be predicted based on actual refraction, corneal power, tIOL power and the measured axis, and a simulation of the tIOL axis rotation enables the best orientation with the lowest refractive cylinder at the spectacle plane to be found.
DOI der Erstveröffentlichung: 10.3390/diagnostics16071029
URL der Erstveröffentlichung: https://doi.org/10.3390/diagnostics16071029
Link zu diesem Datensatz: urn:nbn:de:bsz:291--ds-474686
hdl:20.500.11880/41509
http://dx.doi.org/10.22028/D291-47468
ISSN: 2075-4418
Datum des Eintrags: 14-Apr-2026
Fakultät: M - Medizinische Fakultät
Fachrichtung: M - Augenheilkunde
Professur: M - Univ.-Prof. Dr. Dipl.-Ing. Achim Langenbucher
M - Prof. Dr. med. Nóra Szentmáry
Sammlung:SciDok - Der Wissenschaftsserver der Universität des Saarlandes

Dateien zu diesem Datensatz:
Datei Beschreibung GrößeFormat 
diagnostics-16-01029.pdf974,15 kBAdobe PDFÖffnen/Anzeigen


Diese Ressource wurde unter folgender Copyright-Bestimmung veröffentlicht: Lizenz von Creative Commons Creative Commons